Add better RPi power status reporting (#221)
This commit is contained in:
@@ -106,11 +106,31 @@ def check_rpi_power_status():
|
|||||||
full_cmd = "vcgencmd get_throttled | cut -d= -f2"
|
full_cmd = "vcgencmd get_throttled | cut -d= -f2"
|
||||||
throttled = subprocess.Popen(full_cmd, shell=True, stdout=subprocess.PIPE).communicate()[0]
|
throttled = subprocess.Popen(full_cmd, shell=True, stdout=subprocess.PIPE).communicate()[0]
|
||||||
throttled = throttled.decode('utf-8').strip()
|
throttled = throttled.decode('utf-8').strip()
|
||||||
|
throttled_val = int(throttled, 16)
|
||||||
|
|
||||||
|
if throttled_val & 1<<0:
|
||||||
|
return "Under-voltage"
|
||||||
|
if throttled_val & 1<<3:
|
||||||
|
return "Soft temperature limit"
|
||||||
|
if throttled_val & 1<<1:
|
||||||
|
return "ARM frequency capped"
|
||||||
|
if throttled_val & 1<<2:
|
||||||
|
return "Throttled"
|
||||||
|
|
||||||
|
# These are "previous" statuses here for completeness
|
||||||
|
# Home Assistant has the history so do not report them
|
||||||
|
#
|
||||||
|
#if throttled_val & 1<<16:
|
||||||
|
# return "Previous under-voltage"
|
||||||
|
#if throttled_val & 1<<17:
|
||||||
|
# return "Previous ARM frequency cap"
|
||||||
|
#if throttled_val & 1<<18:
|
||||||
|
# return "Previous throttling"
|
||||||
|
#if throttled_val & 1<<19:
|
||||||
|
# return "Previous soft temperature limit"
|
||||||
|
|
||||||
|
return "OK"
|
||||||
|
|
||||||
if throttled == "0x0":
|
|
||||||
return "OK"
|
|
||||||
else:
|
|
||||||
return "KO"
|
|
||||||
except Exception as e:
|
except Exception as e:
|
||||||
return "Error: " + str(e)
|
return "Error: " + str(e)
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue